Electrical Installation Guide 2007 Edition - Schneider Electric

A
General rules of electrical installation design
  This chapter presents the general rules for designing an installation and presents the involved IEC standards. It gives help in calculation of installed power loads.
B
Connecting to the MV utility distribution network
  This chapter presents the main methods of connection to the MV utility distribution network.
C
Connecting to the LV utility distribution network
  This chapter presents the main methods of connection to the LV utility distribution network.
D
MV & LV architecture selection guide
  Given a particular building, we show how to select the right solution during pre-design and budget step: find a compromise between costs and ratings of the installation during its whole life cycle.
E
LV Distribution
  Conception rules of an electrical installation. System earthings.
F
Protection against electric shocks
  Power monitoring and control system contributes to global "energy efficiency". Such a system is of high benefice for the owner of an electrical network.
G
Sizing and protection of conductors
  Practical methods for conductor sizing and protection are given.
H
LV switchgears : functions & selection
  The basic functions of LV switchgear are described, as well as the selection rules for ensuring the protection coordination.
J
Protection against voltage surges in LV
  The effects of lightning are described. Protective devices are proposed and implementation rules are given.
K
Energy Efficiency in electrical distribution part 1 and part 2
  Power monitoring and control system contributes to global "energy efficiency". Such a system is of high benefice for the owner of an electrical network.
L
Power factor correction and harmonic filtering
  This chapter explains how power factor correction is implemented in LV electrical installation. Practical examples are given.
M
Harmonic management
  The origin and effects of harmonics are described. Measurement and filtering methods are proposed.
N
Characteristics of particular sources and loads
  Specific sources and loads are studied : generators, inverters, induction motors, lighting circuits, LV/LV transformers.....
P
Residential and other special locations
  The specific installations rules applicable to residential premises and some other locations are presented.
Q
EMC guidelines
  This chapter describes the basic rules for ensuring EMC : earthing principles, cable lay-out, wiring recommendations.